BioStar 2 - Differerence with BioStar 1 FE and SE Versions

BioStar 2 - Differerence with BioStar 1 FE and SE Versions

BioStar 2 vs BioStar 1 Feature Comparison Overview

BioStar 2 was created with fundamental conceptual changes to overcome the systematic limitation in BioStar 1.x and to provide consistent performance. So, it's important to know the changes and differences precisely and design a system that can make full use of each feature.


Device Connection – Server/Direct Mode

With BioStar 1.x, there are functional differences according to direct mode or server mode. In order to use a realtime log update and device auto reconnection, it is necessary to use server mode, not direct mode. So, first time users often get confused with the connection mode and may have a chance to make a mistake. With BioStar 2, there is no functional difference between server mode and direct mode, and only has a direction difference. So, users can choose a device connection between Device → Server and Server → Device. So, users can make a device to find a server and try to make a connection, or can search and establish the device connection from the server. The default mode is Server → Device.

In order to prevent any device IP change attempts, it's necessary and recommended to use Device → Server direction mode.


Master/Slave Device

With BioStar 1.x, both Master and slave devices have user data and make an authentication decision. This structure was found to cause slow user data update and transfer speed between the devices connected through RS485 serial communication. So, Users often have to need to wait for an extended time to transfer the large number of user data to all the connected devices. In order to breakthrough this inconvenience and provide more consistent fast performance, BioStar 2 is designed to use slave devices as dummy reader only, which means slave devices do not have user data and make a matching, but only to send input credential data to its master device. With this change, one master device becomes able to support up to 31 slave devices, and can be used with up to eight fingerprint devices.

Access Group & Access Level

BioStar 2 supports 'Access Level' for more easier combination settings as a group of door-plus-timezone. With this layer, users can be more simply managed and allocated to access groups, and more number of combinations can be made to use full system spec.

One user can be assigned up to 16 access groups, and the number of door limitation for one access group is lifted with the advantage of access level.




The additional advantage of Access Group
  • By setting a user group to a access group, it can automatically assign the same access group to new users in the user group
  • By creating a certain access group with VIP or management members, it can be easy to set the access group to be 'Bypass Group' for zones, such as APB and Scheduled Lock. So, the access group members can enter and exit doors without limitation.
    • Related Articles

    • BioStar 2 - How to activate SE License

      How to activate or generate BioStar 2 license? First of all, please purchase the license key and receive it from the EasySecure sales team.  And then, follow the below procedure. 1. Go to the setting and click SERVER.  2. Check if the server is ...
    • BioStar 2 - What are the differences between the T&A Free & SE version

      In BioStar 2 there is a possibility to get a paid license for the T&A function, the main difference is that in the free version the following amount of users and schedules can be used: - 99 Users - 1 Schedule In the paid version (SE) there will be no ...
    • BioStar 1 - How to activate the SE Software License

      Some functions such as attendance reports, fire zones and anti-passback are not available within the free BioStar version. The free version is also limited to a maximum of 20 scanners and after that you need the paid BioStar SE version of the ...
    • BioStar 2 - What are the differences between the Access Control Free & SE version

      In BioStar 2 there is a possibility to get a paid license for the access control functionality. Below you can find a overview of the differences in functionality between the free and SE version. Beware! It is always possible to upgrade your free ...
    • BioStar 1 - How to solve error messages related to BioStar SE License

      BioStar software license allows you to activate BioStar's standard edition features without its USB dongle. The software license is supported by BioStar 1.62 or later. This document shows how to deal with possible error messages you might encounter ...