BioStar 1 - How to set up an anti passback zone

BioStar 1 - How to set up an anti passback zone

Anti-passback is a security mechanism that prevents a person from passing back her access card to the next person. It is designed to prevent the next person from verifying herself with another person's access card. When using BioStar, you can set up an Anti-passback zone, which requires users who've already entered an area to leave the zone first before entering the area again. For instance, if the zone consists of two devices (let's call them Device A and Device B here), the user who's been already verified on Device A must verify herself on Device B before verifying herself on Device A again. 

You can set up an anti-passback zone by performing the following steps: 

1. On the Doors page, click Add New Zone

 

2. Enter a name for the Anti-passback zone and choose Anti-passback Zone from the Type drop-down list. 

 

3. Configure the settings of the Anti-passback zone and add devices to the zone by clicking Add Device

  • APB Type 
    Soft: A user who has broken the Anti-passback rule can enter the area without the administrator explicitly releasing the alarm. 
    Hard: A user who has broken the Anti-passback rule can't enter the area without the administrator explicitly releasing the alarm.
  • In case of Disconnected 
    Door Open: Doors in the zone will get opened when the communication between the master and member devices is disconnected. 
    Door Close: Doors in the zone will get closed when the communication between the master and member devices is disconnected.

 

4. Choose the devices you want to add to the zone as In Device and click the right arrow button. Perform the same for Out Device.

 

5. Click Apply to transfer the settings to the devices.

 

    • Related Articles

    • BioStar 2 - How to set up an anti passback zone

      This document will guide you how to configure Local Anti-Passback zone which is provided without license. RS-485 Mode Local zone means RS-485 based, master device is zone master. Please refer to the below link for RS-485 configuration.  RS485 Mode ...
    • BioStar 2 - Hoe stel ik een anti passback zone in

      Controleer uw BioStar SE licentie voordat u dit artikel leest. De BioStar 2 SE (Standard Edition) licentie moet geactiveerd zijn om de anti passback zone in te kunnen stellen. Zodra de licentie is geactiveerd dan is het tabblad 'zone' beschikbaar in ...
    • EasySecure.cloud - How to setup timed anti-passback

      In this article we will explain how to use the Timed Anti Passback function within the EaySecure Software. With Timed APB you can make sure a user can not enter twice on the same access control scanner within a certain period.  For example:   If you ...
    • EasySecure.cloud - Hoe kan ik timed anti-passback instellen

      In dit artikel leggen we uit hoe u de Timed Anti Passback functie binnen de EaySecure Software kunt gebruiken. Met Timed APB kunt u ervoor zorgen dat een gebruiker binnen een bepaalde periode niet twee keer op dezelfde toegangscontrolescanner kan ...
    • EasySecure.cloud - Wie kann ich timed anti-passback einrichten

      EasySecure - Wie richte ich einen zeitgesteuerten Anti-Passback ein? In diesem Artikel erklären wir Ihnen, wie Sie die Funktion "Timed Anti-Passback" in der EaySecure Software nutzen können. Mit Timed APB können Sie sicherstellen, dass ein Benutzer ...