BioStar 1 - How to get log records from slave devices
When you configure zones on the BioStar client, you need to set master/slave relationships between the devices that belong to the same zone. You can connect the master device with the slave devices via RS485. In this case, you can collect log records of the slave devices through the master device.
In this example, we will set master/slave relationships between devices in the same access zone.
1. For starters, we create an access zone. Go to the Doors page and click Add New Zone.
2. Configure the Add New Zone dialog and click OK.
3. Click Add Device to add devices to the zone. This brings up the Add Device dialog. Choose devices you want to add. The master/slave relationship will be automatically created.
4. Choose the options on the Details tab. You can choose what to synchronize between the devices in the zone.
Synchronize User Info: This automatically synchronizes user information of the devices.
Synchronize Log Data: This automatically synchronizes log records of the devices.
Synchronize Time: This automatically synchronizes the times of the devices.
5. Click Apply to complete the configuration.
Related Articles
BioStar 2 - RS485 Mode (Master, Default, Slave)
This document will guide you to understand the concept of the changed RS485 mode with BioStar 2. RS-485 Mode Three different RS485 modes are supported as below. Default: Factory default status for a device configuration. Master: Devices can search ...
BioStar 2 - How to add devices
Add devices to the BioStar 2 server 1. Go to Device and click Search Device. 2. Select the devices to add to the server. BioStar 2 has two communication modes, Device → Server and Server → Device. No functional difference between the two. ...
BioStar 2 - How to set up a fire alarm zone
To use zone feature, you should activate BioStar2 AC license first. And then, you can use Biostar 2 zone. The concept of Biostar2 fire alarm zone is similar with BioStar version1 like below. Electrical specification If the electrical output of Fire ...
BioStar 2 - How to set up an anti passback zone
This document will guide you how to configure Local Anti-Passback zone which is provided without license. RS-485 Mode Local zone means RS-485 based, master device is zone master. Please refer to the below link for RS-485 configuration. RS485 Mode ...
BioStar 2 - How to set BioStar and device time
This document will guide you to understand a way to set BioStar 2 and device time properly. Server Time Setting 1. Go to Setting > Preference. 2. With BioStar 2, the server UTC time zone is selectable. By changing the time setting, you can see the ...